Six tests that tell you whether the encoder, the cable, or the drive is the real fault — before you spend money.
| Symptom | Likely cause | Action |
|---|---|---|
| A/B counts drift under load | Coupling slip or loose encoder mounting | Re-torque coupling, remount encoder |
| Zero pulse missing once per rev | Index sensor fault in encoder | Replace encoder |
| Counts jump randomly | Shield grounding or cable interference | Re-route cable, check shield |
| Encoder very hot to touch | Over-voltage supply or wrong variant | Verify 5V/24V supply and variant |
| Drive shows encoder alarm only at speed | Signal amplitude loss at high RPM | Replace encoder or cable |
Replacement encoders are selected by motor MPN, resolution (PPR), output type (TTL/HTL/push-pull) and interface (incremental/absolute). Send us the motor nameplate or the old encoder label and we confirm the exact match — free of charge.
A shorted encoder can stress the drive's feedback supply. Swap in a known-good encoder or test the supply before reconnecting.
10+ years in clean service; much less with oil ingress, vibration or belt dust. Encoders on fan/pump VFDs often outlive the drive.
Yes — send the motor MPN or the old encoder label, and we supply the encoder with coupling and mounting hardware.